Full Text:   <3552>

CLC number: TM343

On-line Access: 

Received: 2007-06-08

Revision Accepted: 2007-08-31

Crosschecked: 0000-00-00

Cited: 0

Clicked: 5640

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
Open peer comments

Journal of Zhejiang University SCIENCE A 2008 Vol.9 No.2 P.165-172

http://doi.org/10.1631/jzus.A071297


Diagnosis of stator faults in induction motor based on zero sequence voltage after switch-off


Author(s):  Jia-qiang YANG, Jin HUANG, Tong LIU

Affiliation(s):  School of Electrical Engineering, Zhejiang University, Hangzhou 310027, China

Corresponding email(s):   ee_huangj@emb.zju.edu.cn

Key Words:  Induction motor, Stator fault diagnosis, Hilbert-Huang transform (HHT), Zero sequence voltage, Empirical mode decomposition (EMD)


Jia-qiang YANG, Jin HUANG, Tong LIU. Diagnosis of stator faults in induction motor based on zero sequence voltage after switch-off[J]. Journal of Zhejiang University Science A, 2008, 9(2): 165-172.

@article{title="Diagnosis of stator faults in induction motor based on zero sequence voltage after switch-off",
author="Jia-qiang YANG, Jin HUANG, Tong LIU",
journal="Journal of Zhejiang University Science A",
volume="9",
number="2",
pages="165-172",
year="2008",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A071297"
}

%0 Journal Article
%T Diagnosis of stator faults in induction motor based on zero sequence voltage after switch-off
%A Jia-qiang YANG
%A Jin HUANG
%A Tong LIU
%J Journal of Zhejiang University SCIENCE A
%V 9
%N 2
%P 165-172
%@ 1673-565X
%D 2008
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A071297

TY - JOUR
T1 - Diagnosis of stator faults in induction motor based on zero sequence voltage after switch-off
A1 - Jia-qiang YANG
A1 - Jin HUANG
A1 - Tong LIU
J0 - Journal of Zhejiang University Science A
VL - 9
IS - 2
SP - 165
EP - 172
%@ 1673-565X
Y1 - 2008
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A071297


Abstract: 
To improve the accuracy of the stator winding fault diagnosis in induction motor, a new diagnostic method based on the hilbert-Huang transform (HHT) was proposed. The ratio of fundamental zero sequence voltage to positive sequence voltage after switch-off was selected as the stator fault characteristic, which could effectively avoid the influence of the supply unbalance and the load fluctuation, and directly represent the asymmetry in the stator. Using the empirical mode decomposition (EMD) based on HHT, the zero sequence voltage after switch-off was decomposed and the fundamental component was extracted. Then, the fault characteristic can be acquired. Experimental results on a 4-kW induction motor demonstrate the feasibility and effectiveness of this method.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1] Albizu, I., Zamora, I., Mazon, A.J., Tapia, A., 2006. Techniques for online diagnosis of stator shorted turns in induction motors. Electric Power Components and Systems, 34(1):97-114.

[2] Arkan, M., Perovic, D.K., Unsworth, P., 2001. Online stator fault diagnosis in induction motors. IEE Proc.-Electric Power Appl., 148(6):537-547.

[3] Bachir, S., Tnani, S., Trigeassou, J.C., Champenois, G., 2006. Diagnosis by parameter estimation of stator and rotor faults occurring in induction machines. IEEE Trans. on Ind. Electr., 53(3):963-973.

[4] Cash, M.A., Habetler, T.G., Kliman, G.B., 1998. Insulation failure prediction in AC machines using line-neutral voltages. IEEE Trans. on Ind. Appl., 34(6):1234-1238.

[5] Cruz, S.M.A., Cardoso, A.J.M., 2005. Multiple reference frames theory: a new method for the diagnosis of stator faults in three-phase induction motors. IEEE Trans. on Energy Conv., 20(3):611-619.

[6] Garcia, P., Briz, F., Degner, M.W., Diez, A.B., 2004. Diagnostics of Induction Machines Using the Zero Sequence Voltage. Conf. Record of the 2004 IEEE Industry Applications Conf. Piscataway, NJ, USA, p.735-742.

[7] Huang, N.E., Shen, Z., Long, S.R., Wu, M.C., Shin, H.H., Zheng, Q., Yen, N.C., Tung, C.C., Liu, H.H., 1998. The Empirical Mode Decomposition and the Hilbert Spectrum for Nonlinear and Non-stationary Time Series Analysis. Proc. Royal Society of London, Series A, p.903-995.

[8] Kliman, G.B., Premerlani, W.J., Koegl, R.A., Hoeweler, D., 1996. A New Approach to On-line Turn Fault Detection in AC Motors. Conf. Record of the 1996 IEEE Industry Applications Conf. Piscataway, NJ, USA, p.687-693.

[9] Mirafzal, B., Demerdash, N.A.O., 2006. On innovative methods of induction motor interturn and broken-bar fault diagnostics. IEEE Trans. on Ind. Appl., 42(2):405-414.

[10] Nandi, S., 2005. Stator Fault Detection in Induction Machines Using Triplen Harmonics at Motor Terminal Voltage after Switch-off. IEEE Power Engineering Society General Meeting. New York, NY, USA, p.1897-1902.

[11] Nandi, S., Toliyat, H.A., 2002. Novel frequency-domain-based technique to detect stator interturn faults in induction machines using stator-induced voltages after switch-off. IEEE Trans. on Ind. Appl., 38(1):101-109.

[12] Nandi, S., Toliyat, H.A., Li, X.D., 2005. Condition monitoring and fault diagnosis of electrical motors—a review. IEEE Trans. on Energy Conv., 20(4):719-729.

[13] Sottile, J.Jr., Kohler, J.L., 1993. An on-line method to detect incipient failure of turn insulation in random-wound motors. IEEE Trans. on Energy Conv., 8(4):762-768.

[14] Trutt, F.C., Sottile, J., Kohler, J.L., 2002. Online condition monitoring of induction motors. IEEE Trans. on Ind. Appl., 38(6):1627-1632.

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE