CLC number: TM301.4
On-line Access: 2018-11-02
Received: 2017-12-01
Revision Accepted: 2018-06-05
Crosschecked: 2018-10-29
Cited: 0
Clicked: 4361
Wei Chen, Gui-chu Wu, You-tong Fang, Ji-en Ma. Thermal optimization of a totally enclosed forced ventilated permanent magnet traction motor using lumped parameter and partial computational fluid dynamics modeling[J]. Journal of Zhejiang University Science A, 2018, 19(11): 878-888.
@article{title="Thermal optimization of a totally enclosed forced ventilated permanent magnet traction motor using lumped parameter and partial computational fluid dynamics modeling",
author="Wei Chen, Gui-chu Wu, You-tong Fang, Ji-en Ma",
journal="Journal of Zhejiang University Science A",
volume="19",
number="11",
pages="878-888",
year="2018",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.A1700649"
}
%0 Journal Article
%T Thermal optimization of a totally enclosed forced ventilated permanent magnet traction motor using lumped parameter and partial computational fluid dynamics modeling
%A Wei Chen
%A Gui-chu Wu
%A You-tong Fang
%A Ji-en Ma
%J Journal of Zhejiang University SCIENCE A
%V 19
%N 11
%P 878-888
%@ 1673-565X
%D 2018
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.A1700649
TY - JOUR
T1 - Thermal optimization of a totally enclosed forced ventilated permanent magnet traction motor using lumped parameter and partial computational fluid dynamics modeling
A1 - Wei Chen
A1 - Gui-chu Wu
A1 - You-tong Fang
A1 - Ji-en Ma
J0 - Journal of Zhejiang University Science A
VL - 19
IS - 11
SP - 878
EP - 888
%@ 1673-565X
Y1 - 2018
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.A1700649
Abstract: In this study, we present a thermal optimization method using the overall lumped parameter (LP) and partial computational fluid dynamics (CFD) modeling for a 600-kW permanent magnet traction motor developed for high-speed trains. The motor is totally enclosed forced ventilated to achieve high power density, high efficiency, and low maintenance requirements. Considering the electro-magnetic performance, bogie space, and thermal capacity, we propose a ventilation structure with zigzag plates in sector cross-section. We focus particularly on the ventilation channels and propose an overall LP model for thermal optimization, in which the full consideration of the influence of turbulent flow is given by using a partial CFD model. Given the specific critical parameters from the optimization results, we present a complete 3D CFD model of the whole motor to obtain an accurate temperature distribution and the maximum temperature rises in local points. The benefit of zigzag plates is studied extensively using both the LP and the complete CFD models and the results are verified by equivalent thermal experiments under rated operations. Experimental results indicate that the ventilation structure fulfills the normal operational demands of high-speed trains by improving thermal performance by more than 15%. Additionally, we propose an engineering method to estimate iron loss constraint with the complete CFD model to guide the control system design.
This paper presents thermal issue in a traction motor. Power loss and thermal design is among the key issues of motor design and optimization. In this paper, the thermal analysis is based on lumped parameter method, and CFD is used for determining some coefficients. The analysis is verified by experiments.
[1]Bergman TL, Incropera FP, DeWitt DP, et al., 1990. Fundamentals of Heat and Mass Transfer. John Wiley & Sons, USA.
[2]Boglietti A, Cavagnino A, 2007. Analysis of the endwinding cooling effects in TEFC induction motors. IEEE Transactions on Industry Applications, 43(5):1214-1222.
[3]Boglietti A, Cavagnino A, Staton D, 2008. Determination of critical parameters in electrical machine thermal models. IEEE Transactions on Industry Applications, 44(4):1150-1159.
[4]Boglietti A, Cavagnino A, Staton D, et al., 2009. Evolution and modern approaches for thermal analysis of electrical machines. IEEE Transactions on Industrial Electronics, 56(3):871-882.
[5]Chowdhury SK, Baski PK, 2010. A simple lumped parameter thermal model for electrical machine of TEFC design. Joint International Conference on Power Electronics, Drives, and Energy Systems & Power India, p.1-7.
[6]El-Refaie AM, Jahns TM, Mccleer PJ, et al., 2006. Experimental verification of optimal flux weakening in surface PM machines using concentrated windings. IEEE Transactions on Industry Applications, 42(2):443-453.
[7]Feng J, 2012. Development overview and application challenges of permanent magnet synchronous traction system for rail transit. High Power Converter Technology, 3:1-7 (in Chinese).
[8]Hao H, Fei WZ, Miao DM, et al., 2016. Torque characteristics in a large permanent magnet synchronous generator with stator radial ventilating air ducts. Frontiers of Information Technology and Electronic Engineering, 17(8):814-824.
[9]He HB, Yao DW, Wu F, 2017. A reduced and optimized kinetic mechanism for coke oven gas as a clean alternative vehicle fuel. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 18(2):511-530.
[10]Huang XY, Zhang JC, Sun CM, et al., 2015. A combined simulation of high speed train permanent magnet traction system using dynamic reluctance mesh model and Simulink. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 16(8):607-615.
[11]Huang Y, Zhu J, Guo Y, 2009. Thermal analysis of highspeed SMC motor based on thermal network and 3-D FEA with rotational core loss included. IEEE Transactions on Magnetics, 45(10):4680-4683.
[12]Ji SM, Ge JQ, Tan DP, 2017. Wall contact effects of particle-wall collision process in a two-phase particle fluid. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 18(3):958-973.
[13]Jungreuthmayer C, Bauml T, Winter O, et al., 2011. A detailed heat and fluid flow analysis of an internal permanent magnet synchronous machine by means of computational fluid dynamics. IEEE Transactions on Industrial Electronics, 59(12):4568-4578.
[14]Kral C, Haumer A, Bauml T, 2008. Thermal model and behavior of a totally-enclosed-water-cooled squirrel-cage induction machine for traction applications. IEEE Transactions on Industrial Electronics, 55(10):3555-3565.
[15]Kral C, Haumer A, Haigis M, et al., 2009. Comparison of a CFD analysis and a thermal equivalent circuit model of a TEFC induction machine with measurements. IEEE Transactions on Energy Conversion, 24(4):809-818.
[16]Li Q, Zhong J, Li Y, et al., 2010. Study on a C-class solvent-free silicone impregnating varnish. IEEE Transactions on Dielectrics and Electrical Insulation, 17(3):785-790.
[17]Mademlis C, Kioskeridis I, Margaris N, 2004. Optimal efficiency control strategy for interior permanent-magnet synchronous motor drives. IEEE Transactions on Energy Conversion, 19(4):715-723.
[18]Mellor PH, Roberts D, Turner DR, 1991. Lumped parameter thermal model for electrical machines of TEFC design. IEE Proceedings B (Electric Power Applications), 138(5):205-218.
[19]Mi C, Slemon GR, Bonert R, 2003. Modeling of iron losses of permanent-magnet synchronous motors. IEEE Transactions on Industry Applications, 39(3):734-742.
[20]Micallef C, 2006. End Winding Cooling in Electric Machines. PhD Thesis, University of Nottingham, Nottingham, UK.
[21]Mizuno S, Noda S, Matsushita M, et al., 2013. Development of a totally enclosed fan-cooled traction motor. IEEE Transactions on Industry Applications, 49(4):1508-1514.
[22]Nategh S, Wallmark O, Leksell M, et al., 2012. Thermal analysis of a PMaSRM using partial FEA and lumped parameter modeling. IEEE Transactions on Energy Conversion, 27(2):477-488.
[23]Nategh S, Huang Z, Krings A, et al., 2013. Thermal modeling of directly cooled electric machines using lumped parameter and limited CFD analysis. IEEE Transactions on Energy Conversion, 28(4):979-990.
[24]Qian JY, Liu BZ, Jin ZJ, et al., 2016. Numerical analysis of flow and cavitation characteristics in a pilot-control globe valve with different valve core displacements. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 17(5):54-64.
[25]Shih TH, Liou WW, Shabbir A, et al., 1995. A new k-ε eddy viscosity model for high Reynolds number turbulent flows. Computers & Fluids, 24(3):227-238.
[26]Taguchi G, Chowdhury S, Wu Y, 2007. Introduction to orthogonal arrays. In: Taguchi’s Quality Engineering Handbook. John Wiley & Sons, USA, p.584-596.
[27]Tan Z, Song XG, Ji B, et al., 2015. 3D thermal analysis of a permanent magnet motor with cooling fans. Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering), 16(8):616-621.
[28]Wei Y, Meng D, Wen J, 1998. Heat Transfer in Motors. China Machine Press, Beijing, China (in Chinese).
[29]Wesseling P, 2001. Principles of Computational Fluid Dynamics. Springer, New York, USA.
Open peer comments: Debate/Discuss/Question/Opinion