RESEARCH ON THE METHODS OF DETECTING AND REMOVING SLIDE VALVE FAILURE


Author(s):  LI Wei, LI Wei-bo, WU Gen-mao, WEI Jian-hua

Affiliation(s):  State Key Laboratory of Fluid Power Transmission and Control, Yuquan Campus of Zhejiang University, Hangzhou, 310027, China

Corresponding email(s): 

Key Words:  fault-tolerant control, failure diagnosis, trouble removal, slide valve, hydraulic sticking


Share this article to: More

LI Wei, LI Wei-bo, WU Gen-mao, WEI Jian-hua. RESEARCH ON THE METHODS OF DETECTING AND REMOVING SLIDE VALVE FAILURE[J]. Journal of Zhejiang University Science A, 2000, 1(1): 56-60.

@article{title="RESEARCH ON THE METHODS OF DETECTING AND REMOVING SLIDE VALVE FAILURE",
author="LI Wei, LI Wei-bo, WU Gen-mao, WEI Jian-hua",
journal="Journal of Zhejiang University Science A",
volume="1",
number="1",
pages="56-60",
year="2000",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.2000.0056"
}

%0 Journal Article
%T RESEARCH ON THE METHODS OF DETECTING AND REMOVING SLIDE VALVE FAILURE
%A LI Wei
%A LI Wei-bo
%A WU Gen-mao
%A WEI Jian-hua
%J Journal of Zhejiang University SCIENCE A
%V 1
%N 1
%P 56-60
%@ 1869-1951
%D 2000
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.2000.0056

TY - JOUR
T1 - RESEARCH ON THE METHODS OF DETECTING AND REMOVING SLIDE VALVE FAILURE
A1 - LI Wei
A1 - LI Wei-bo
A1 - WU Gen-mao
A1 - WEI Jian-hua
J0 - Journal of Zhejiang University Science A
VL - 1
IS - 1
SP - 56
EP - 60
%@ 1869-1951
Y1 - 2000
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.2000.0056


Abstract: 
Various ways for detecting slide valve failure are discussed in the paper. Specifically, a new method for detecting slide valve sticking state is first presented. The method does not depend on any special sensor and is only based on the detection of oscillation current wave within a valve coil. Results of theoretical analysis and experimental research are given for comparison. In order to remove a slide valve sticking online, a concept and method of "electrical hammer" is introduced. At last, an application example of the methods is discussed. In fact, it is an electro-hydraulic turbine system with failure diagnosis, fault-tolerant and trouble removal functions.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Liou Xihui, 1987. Static and dynamic characteristic of proportional control amplifier and proportional electromagnet. Master thesis, Hangzhou, Zhejiang University.

[2]Li wei, Wang Ruiming, Ge Yiyuan, 1997. Research on the Method of Removing Spool Sticking Online. '97 ICFP. International academic publishers, Beijing, p.485-489.

[3]Lu Yongxiang,Hu Dahong,1988. Electro-hydraulic Proportional Control Technique, Publishing Company of Mechanical Industry,Beijing,p.56-66.

[4]Wang Ruiming,1998. Study on the control system of ASIC-PLC based on water turbine velometer.Master's thesis,Huangzhou,Zhejiang University

[5]Wei Jianhua,Lu Yongxiang,Wu Genmao,1995. Fault-tolerant Based Electro-hydraulic Executive Device of Steam Turbine.Power Engineering,15(4): 15-18.