Full Text:   <2910>

CLC number: TP393.04

On-line Access: 

Received: 2002-09-11

Revision Accepted: 2003-02-10

Crosschecked: 0000-00-00

Cited: 0

Clicked: 5820

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
1. Reference List
Open peer comments

Journal of Zhejiang University SCIENCE A 2004 Vol.5 No.1 P.22-30

http://doi.org/10.1631/jzus.2004.0022


A hierarchical architecture of centralized monitoring and controlling system and its high-performance and interoperability protocol


Author(s):  HUANG Li-can, WU Zhao-hui, PAN Yun-he

Affiliation(s):  College of Computer Science, Zhejiang University, Hangzhou 310027, China

Corresponding email(s):   lchuang@cs.zju.edu.cn

Key Words:  Monitoring and controlling system, Protocol, Architecture


Share this article to: More

HUANG Li-can, WU Zhao-hui, PAN Yun-he. A hierarchical architecture of centralized monitoring and controlling system and its high-performance and interoperability protocol[J]. Journal of Zhejiang University Science A, 2004, 5(1): 22-30.

@article{title="A hierarchical architecture of centralized monitoring and controlling system and its high-performance and interoperability protocol",
author="HUANG Li-can, WU Zhao-hui, PAN Yun-he",
journal="Journal of Zhejiang University Science A",
volume="5",
number="1",
pages="22-30",
year="2004",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.2004.0022"
}

%0 Journal Article
%T A hierarchical architecture of centralized monitoring and controlling system and its high-performance and interoperability protocol
%A HUANG Li-can
%A WU Zhao-hui
%A PAN Yun-he
%J Journal of Zhejiang University SCIENCE A
%V 5
%N 1
%P 22-30
%@ 1869-1951
%D 2004
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.2004.0022

TY - JOUR
T1 - A hierarchical architecture of centralized monitoring and controlling system and its high-performance and interoperability protocol
A1 - HUANG Li-can
A1 - WU Zhao-hui
A1 - PAN Yun-he
J0 - Journal of Zhejiang University Science A
VL - 5
IS - 1
SP - 22
EP - 30
%@ 1869-1951
Y1 - 2004
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.2004.0022


Abstract: 
This paper describes a hierarchical architecture and a high-performance and interoperability protocol for centralized monitoring and controlling systems (CMCS). The protocol we proposed can interoperate different monitoring and controlling systems constructed by different companies, each with different functions and communication protocols. The protocol reduces the amount of traffic and has real-time and high-performance advantages. The protocol was implemented in CMCS for telecommunication power supply and air-conditioner used by the Telecommunication Bureau of Zhejiang Province. This paper deals with the hierarchical architecture and function of CMCS and packet format, command ID, and SDL description of its protocol. We also discuss the properties of the interoperability and performance of the protocol in this paper.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1] Belina, F., Hogrefe, D. and Sarma, A., 1991. SDL with Applications from Protocol Specification. Carl Hansiger Verlag and Prentice Hall International.

[2] Huang, L.C., 1999. SC-SS interconnected protocol of centralized monitoring and controlling system of power supply and air-conditioner (temporary specifications). Zhejiang Post and Telecommunication Management Bureau in China.

[3] Huang, L.C. and Wu, Z.H., 2001. An SC-SS interconnected protocol between heterogeneous and distributed monitoring and controlling systems. Proceedings of the Sixth International Conference for young computer scientist ICYCS2001, International Academic Publishers, p.188-192.

[4] ITU-T, 1992. Message Sequence Charts (MSC). International Standard ITU-T Recommendation Z.120, 1992.

[5] ITU-T, 1995. ITU Recommendation Z.105, SDL Combined with ASN.1 (SDL/ASN.1), 1995.

[6] ITU-T, 1998a. Information Technology-Abstract Syntax Notation One (ASN.1): Specification of Basic Notation., International Standard ITU-T Rec.X.680,1997|ISO/IEC 8824-1, 1998.

[7] ITU-T, 1998b. Information technology - ASN.1 encoding rules: Specification of Packed Encoding Rules (PER)., International Standard ITU-T Rec. X.691, 1997 | ISO/IEC 8825-2, 1998.

[8] ITU-T, 2000. ITU-T Recommendation Z.100: Specification and Description Language (SDL), ITU, Geneva.

[9] Khendek, F. and Vincent, D., 2000. Enriching SDL specifications with MSCs. 2nd Workshop on SDL and MSC, Grenoble, p.26-28.

[10] Ministry of Posts and Telecommunications of China, 1997. Technological requirements of centralized monitoring and controlling system of telecommunication power supply and air-conditioner (temporary specifications).

[11] Olivier, D., 2002. ASN.1: The solution for efficient communication between systems, http://asn1.elibel.tm.fr/biblio/asn1-presentation-fichiers/frame.htm.

[12] Sidnie, M. F., 1995. SNMP: A Guide to Network Management. New York, McGraw-Hill.

[13] Telecommunication General Bureau of China, 1997a. Centralized monitoring and controlling system of telecommunication power supply and air-conditioner (temporary standards) .

[14] Telecommunication General Bureau of China, 1997b. Technological requirements for selecting systems of centralized monitoring and controlling system of telecommunication power supply and air-conditioner.

[15] Telelogic Company, 2002.Telelogic Tau SDL suite, http://www.telelogic.com/

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE