CLC number: R783.4; R783.6
On-line Access: 2024-08-27
Received: 2023-10-17
Revision Accepted: 2024-05-08
Crosschecked: 2013-05-17
Cited: 0
Clicked: 5514
Zhen-zhen Peng, Xin-min Chen, Jun Wang, Ai-jie Li, Zu-jie Xu. Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading[J]. Journal of Zhejiang University Science B,in press.Frontiers of Information Technology & Electronic Engineering,in press.https://doi.org/10.1631/jzus.B1200264 @article{title="Effect of proximal contact strength on the three-dimensional displacements of implant-supported cantilever fixed partial dentures under axial loading", %0 Journal Article TY - JOUR
Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article
Reference[1]Adell, R., Lekholm, U., Rockler, B., Brånemark, P.I., 1981. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int. J. Oral Surg., 10(6):387-416. ![]() [2]Adell, R., Eriksson, B., Lekholm, U., Brånemark, P.I., Jemt, T., 1990. Long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int. J. Oral Maxillofac. Implants, 5(4):347-359. ![]() [3]Aglietta, M., Siciliano, V.I., Zwahlen, M., Brägger, U., Pjetursson, B.E., Lang, N.P., Salvi, G.E., 2009. A systematic review of the survival and complication rates of implant supported fixed dental prostheses with cantilever extensions after an observation period of at least 5 years. Clin. Oral Implants Res., 20(5):441-451. ![]() [4]Andersen, A.C., Good, L.S., 1970. The beagle as an experimental dog. Science, 170(3959):723. ![]() [5]Arısan, V., Anıl, A., Wolke, J.G., Özer, K., 2010. The effect of injectable calcium phosphate cement on bone anchorage of titanium implants: an experimental feasibility study in dogs. Int. J. Oral Maxillofac. Surg., 39(5):463-468. ![]() [6]Batista, L.R., Muramatsu, M., Campos, T.N., 2003. Stress analysis of fresh, fixed and macerated dog mandibles— holographic interferometric double exposition method. Proc. SPIE, 4829:1012-1013. ![]() [7]Becker, C.M., 2004. Cantilever fixed prostheses utilizing dental implants: a 10-year retrospective analysis. Quintessence Int., 35(6):437-441. ![]() [8]Becker, C.M., Kaiser, D.A., 2000. Implant-retained cantilever fixed prosthesis: where and when. J. Prosthet. Dent., 84(4):432-435. ![]() [9]Branemark, P.I., Zarb, G.A., Albrektsson,, T., Rosen, H.M., 1986. Tissue-integrated prostheses. osseointegration in clinical dentistry. Plastic Reconstruc. Surg., 77(3):496-497. ![]() [10]Campos, T.N., Adachi, L.K., Chorres, J.E., Campos, A.C., Muramatsu, M., Gioso, M.A., 2006. Holographic interferometry method for assessment of static load stress distribution in dog mandible. Brazilian Dent. J., 17(4):279-284. ![]() [11]Çehreli, M.C., Iplikçioglu, H., 2002. In vitro strain gauge analysis of axial and off-axial loading on implant supported fixed partial dentures. Implant Dent., 11(3):286-292. ![]() [12]Chen, F., Brown, G.M., Song, M., 2000. Overview of three-dimensional shape measurement using optical methods. Opt. Eng., 39(1):10-22. ![]() [13]Chen, T.Y., Chang, G.L., Wu, S.H., 1995. Holographic evaluation of the marginal fits of complete crowns loaded at the central fossa. Opt. Eng., 34(5):1364-1368. ![]() [14]Chorres, J.E., Uono, C., Gioso, M.A., Batista, L., Muramatsu, M., Campos, T.N., 2005. Qualitative analysis of stress distribution in tooth-implant and implant-supported prosthesis by means of holography interferometry method. RPG Rev. Pos. Grad., 12(4):412-416. ![]() [15]Coelho, P.G., Granato, R., Marin, C., Bonfante, E.A., Janal, M.N., Suzuki, M., 2010a. Biomechanical and bone histomorphologic evaluation of four surfaces on plateau root form implants: an experimental study in dogs. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod., 109(5):e39-e45. ![]() [16]Coelho, P.G., Marin, C., Granato, R., Bonfante, E.A., Lima, C.P., Suzuki, M., 2010b. Surface treatment at the cervical region and its effect on bone maintenance after immediate implantation: an experimental study in dogs. Oral Surg. Oral Med. Oral Pathol. Oral Radiol. Endod., 110(2):182-187. ![]() [17]Dörfer, C.E., von Bethlenfalvy, E.R., Staehle, H.J., Pioch, T., 2000. Factors influencing proximal dental contact strengths. Eur. J. Oral Sci., 108(5):368-377. ![]() [18]Eskitascioglu, G., Usumez, A., Sevimay, M., Soykan, E., Unsal, E., 2004. The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: a three-dimensional finite element study. J. Prosthet. Dent., 91(2):144-150. ![]() [19]Esposito, M., Hirsch, J., Lekholm, U., Thomsen, P., 1998. Biological factors contributing to failures of osseointegrated oral implants. (I) Success criteria and epidemiology. Eur. J. Oral. Sci., 106(1):527-551. ![]() [20]Huang, C.C., Lan, T.H., Lee, H.E., Wang, C.H., 2011. The biomechanical analysis of relative position between implant and alveolar bone: finite element method. J. Periodontol., 82(3):489-496. ![]() [21]Kohavi, D., 1993. Complications in the tissue integrated prostheses components: clinical and mechanical evaluation. J. Oral Rehabil., 20(4):413-422. ![]() [22]Manda, M., Galanis, C., Georgiopoulos, V., Provatidis, C., Koidis, P., 2010. Effect of varying the vertical dimension of connectors of cantilever cross-arch fixed dental prostheses in patients with severely reduced osseous support: a three-dimensional finite element analysis. J. Prosthet. Dent., 103(2):91-100. ![]() [23]Parfitt, G.J., 1960. Measurement of the physiological mobility of individual teeth in an axial direction. J. Dent. Res., 39(3):608-618. ![]() [24]Romeed, S., Fok, S., Wilson, N.H.F., 2004. Finite element analysis of fixed partial denture replacement. J. Oral Rehabil., 31(12):1208-1217. ![]() [25]Salvi, G.E., Brägger, U., 2009. Mechanical and technical risks in implant therapy. Int. J. Oral Maxillofac. Implants, 24(Suppl):69-85. ![]() [26]Sevimay, M., Turhan, F., Kiliçarslan, M.A., Eskitascioglu, G., 2005. Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown. J. Prosthet. Dent., 93(3):227-234. ![]() [27]van Leeuwen, E.J., Maltha, J.C., Kuijpers-Jagtman, A.M., van′t Hof, M.A., 2003. The effect of retention on orthodontic relapse after the use of small continuous or discontinuous forces. An experimental study in beagle dogs. Eur. J. Oral Sci., 111(2):111-116. ![]() [28]Wang, C.H., Lee, H.E., Wang, C.C., Chang, H.P., 1998. Methods to improve a periodontally involved terminal abutment of a cantilever fixed partial denture—a finite element stress analysis. J. Oral Rehabil., 25(4):253-257. ![]() [29]Wang, Q., 2009. Stress distribution of rigid fixed bridge in abutments with mandibular 56 deletion—a three-dimensional finite element analysis. J. Clin. Rehabil. Tissue Eng. Res., 13(17):3361-3364 (in Chinese). ![]() [30]Weinberg, L.A., 1993. The biomechanics of force distribution in implant-supported prostheses. Int. J. Oral Maxillofac. Implants, 8:19. ![]() [31]Xu, Z.J., Chen, X.M., Li, A.J., Chen, Y., Peng, Z.Z., Wang, J., 2013. Measuring three-dimensional displacement of tooth-supported rigid fixed bridge under oblique concentrated loading using digital laser speckle photograph. J. Sichuan Univ. (Med. Sci. Ed.), 44(1):99-103 (in Chinese). ![]() [32]Zhang, Y.Z., Zhou, Y.C., Liu, L., Lu, Y., Hirofumi, Y., 2007. Stabilization of an abutment under a rigidly fixed bridge by holographical-speckle interferometry. J. Zhejiang Univ.-Sci. B, 8(6):416-421. ![]() [33]Zurdo, J., Romao, C., Wennström, J.L., 2009. Survival and complication rates of implant-supported fixed partial dentures with cantilevers: a systematic review. Clin. Oral Implants Res., 20(s4):59-66. ![]() Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou
310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn Copyright © 2000 - 2025 Journal of Zhejiang University-SCIENCE |
Open peer comments: Debate/Discuss/Question/Opinion
<1>