Influence of the ambient air temperature on the electrical contact reliability of electromagnetic relay


Author(s):  YAO Fang, ZHENG Jian-rong, HUANG Zhang-wu

Affiliation(s):  People Electric Appliances Group, Yueqing 32560, China

Corresponding email(s):   yaofang72@163.com

Key Words:  Ambient air temperature, Electromagnetic relay, Electrical contact reliability, Contact resistance, Bounce time


YAO Fang, ZHENG Jian-rong, HUANG Zhang-wu. Influence of the ambient air temperature on the electrical contact reliability of electromagnetic relay[J]. Journal of Zhejiang University Science A, 2007, 8(3): 485-489.

@article{title="Influence of the ambient air temperature on the electrical contact reliability of electromagnetic relay",
author="YAO Fang, ZHENG Jian-rong, HUANG Zhang-wu",
journal="Journal of Zhejiang University Science A",
volume="8",
number="3",
pages="485-489",
year="2007",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.2007.A0485"
}

%0 Journal Article
%T Influence of the ambient air temperature on the electrical contact reliability of electromagnetic relay
%A YAO Fang
%A ZHENG Jian-rong
%A HUANG Zhang-wu
%J Journal of Zhejiang University SCIENCE A
%V 8
%N 3
%P 485-489
%@ 1673-565X
%D 2007
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.2007.A0485

TY - JOUR
T1 - Influence of the ambient air temperature on the electrical contact reliability of electromagnetic relay
A1 - YAO Fang
A1 - ZHENG Jian-rong
A1 - HUANG Zhang-wu
J0 - Journal of Zhejiang University Science A
VL - 8
IS - 3
SP - 485
EP - 489
%@ 1673-565X
Y1 - 2007
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.2007.A0485


Abstract: 
The dynamic contact resistances of HH52P electromagnetic relays are measured under different ambient air temperature. Their diagnostic parameters are extracted and determined. It is found that the ambient air temperature obviously influences some parameters. In order to research its influence on the electrical contact reliability of electromagnetic relay, the statistic analysis is applied to study the static contact resistance, the max of the dynamic contact resistance and the bounce time. It is found that the ambient air temperature regularly influences the three parameters. Thoroughly, the phenomenon is studied and analyzed in the point of material science so as to probe into the essential matter of it.

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1] Boyer, L., 1994. Electrical and physical modeling of contact defects due to fretting. IEEE Transaction on Components, Packaging and Manufacturing Technology, Part A, 17(1):134-141.

[2] Cheng, L.C., 1998. Electrical Contact Theory and its Application. Mechanical Industry Publish House, Beijing (in Chinese).

[3] Hamilton, J.D., 1995. Time Series Analysis. Princeton University Press.

[4] Li, W.H., Liu, G.J., Li, Z.G., 2000. Study and Reliability Analysis on Testing Instrument for Dynamic Contact Resistance on Contact. Proc. Amer. IEEE HOLM Conf., p.109-114.

[5] Lu, J.G., Wang, J.Q., 2004. The Reliability Theory and Application of Low-voltage Protective Apparatus. Mechanical Industry Publish House, Beijing (in Chinese).

[6] Ma, Z.H., 2002. Effect of several metal element on silver matrix contact materials. Material Introduction, 16(11):23-25.

[7] Tamai, T., 1996. Effect of silicone vapor and humidity on contact reliability of micro relay contacts. IEEE Transaction on Components, Packaging and Manufacturing Technology, Part A, 19(3):329-337.