Full Text:   <2705>

CLC number: R687

On-line Access: 2013-06-03

Received: 2013-03-05

Revision Accepted: 2013-06-19

Crosschecked: 2013-08-13

Cited: 0

Clicked: 4042

Citations:  Bibtex RefMan EndNote GB/T7714

-   Go to

Article info.
1. Reference List
Open peer comments

Journal of Zhejiang University SCIENCE B 2013 Vol.14 No.9 P.855-858

http://doi.org/10.1631/jzus.B1300063


Spinous process plate fixation for cervical spinal fusion after spinal trauma: two case reports


Author(s):  Hiroki Hirabayashi, Jun Takahashi, Hiroyuki Hashidate, Nobuhide Ogihara, Keijiro Mukaiyama, Shugo Kuraishi, Masayuki Shimizu, Hiroyuki Nakagawa, Renzo Matsue, Hiroyuki Kato

Affiliation(s):  Department of Orthopedic Surgery, Shinshu University School of Medicine, Nagano 390-8621, Japan

Corresponding email(s):   hirokihi@shinshu-u.ac.jp

Key Words:  Cervical spine, Cervical plate, Posterior fixation, Spinous process, trauma


Hiroki Hirabayashi, Jun Takahashi, Hiroyuki Hashidate, Nobuhide Ogihara, Keijiro Mukaiyama, Shugo Kuraishi, Masayuki Shimizu, Hiroyuki Nakagawa, Renzo Matsue, Hiroyuki Kato. Spinous process plate fixation for cervical spinal fusion after spinal trauma: two case reports[J]. Journal of Zhejiang University Science B, 2013, 14(9): 855-858.

@article{title="Spinous process plate fixation for cervical spinal fusion after spinal trauma: two case reports",
author="Hiroki Hirabayashi, Jun Takahashi, Hiroyuki Hashidate, Nobuhide Ogihara, Keijiro Mukaiyama, Shugo Kuraishi, Masayuki Shimizu, Hiroyuki Nakagawa, Renzo Matsue, Hiroyuki Kato",
journal="Journal of Zhejiang University Science B",
volume="14",
number="9",
pages="855-858",
year="2013",
publisher="Zhejiang University Press & Springer",
doi="10.1631/jzus.B1300063"
}

%0 Journal Article
%T Spinous process plate fixation for cervical spinal fusion after spinal trauma: two case reports
%A Hiroki Hirabayashi
%A Jun Takahashi
%A Hiroyuki Hashidate
%A Nobuhide Ogihara
%A Keijiro Mukaiyama
%A Shugo Kuraishi
%A Masayuki Shimizu
%A Hiroyuki Nakagawa
%A Renzo Matsue
%A Hiroyuki Kato
%J Journal of Zhejiang University SCIENCE B
%V 14
%N 9
%P 855-858
%@ 1673-1581
%D 2013
%I Zhejiang University Press & Springer
%DOI 10.1631/jzus.B1300063

TY - JOUR
T1 - Spinous process plate fixation for cervical spinal fusion after spinal trauma: two case reports
A1 - Hiroki Hirabayashi
A1 - Jun Takahashi
A1 - Hiroyuki Hashidate
A1 - Nobuhide Ogihara
A1 - Keijiro Mukaiyama
A1 - Shugo Kuraishi
A1 - Masayuki Shimizu
A1 - Hiroyuki Nakagawa
A1 - Renzo Matsue
A1 - Hiroyuki Kato
J0 - Journal of Zhejiang University Science B
VL - 14
IS - 9
SP - 855
EP - 858
%@ 1673-1581
Y1 - 2013
PB - Zhejiang University Press & Springer
ER -
DOI - 10.1631/jzus.B1300063


Abstract: 
Posterior cervical fixation with various forms of instrumentation has been used for reconstruction in cases of traumatic disorders and degenerative or tumor-related dysfunction of the cervical spine. Recently, posterior plate and rod techniques using lateral mass screws or pedicle screws have been reported to show excellent fusion rates (Xu et al., 2010). Nevertheless, because such cervical spinal instrumentation requires screw anchorage, which may expose the vertebral artery or neural structures and cause neighboring lateral mass damage, they are not used by some surgeons (Mihara et al., 2001; Xu et al., 2010). A spinous process plate system, S-plate (Kisco Co., Ltd., Kobe, Japan), has been developed for short in situ fusions in selected patients. In this fixation procedure, the spinous processes are securely sandwiched between a pair of spiked plates, which are pressed together by tightening screws that extend through the plates (Neo et al., 2006). To our knowledge, only one report has described this cervical fixation technique, specifically as a salvage operation for failed anterior cervical fusion (Neo et al., 2006).

Darkslateblue:Affiliate; Royal Blue:Author; Turquoise:Article

Reference

[1]Abumi, K., Kaneda, K., 1997. Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine, 22(16):1853-1863.

[2]Abumi, K., Itoh, H., Kaneda, K., 1994. Transpedicular screw fixation for traumatic lesions of the middle and lower cervical spine: description of the techniques and preliminary report. J. Spinal Disord., 7(1):19-28.

[3]Camille, R.R., Saillant, G., Laville, C., Benazet, J.P., 1992. Treatment of lower cervical spinal injuries—C3 to C7. Spine, 17(10S):S442-S446.

[4]Levine, A.M., Mazel, C., Camille, R.R., 1992. Management of fracture separations of the articular mass using posterior cervical plating. Spine, 17(10S):S447-S454.

[5]Mihara, H., Cheng, B.C., David, S.M., Ohnari, K., Zdeblick, T.A., 2001. Biomechanical comparison of posterior cervical fixation. Spine, 26(15):1662-1667.

[6]Neo, M., Fujibayashi, S., Yoshida, M., Nakamura, T., 2006. Spinous process plate fixation as a salvage operation for failed anterior cervical fusion. J. Neurosurg. Spine, 4(1):78-81.

[7]Wang, J.C., Spenciner, D., Robinson, J.C., 2006. SPIRE spinous process stabilization plate: biomechanical evaluation of a novel technology. J. Neurosurg. Spine, 4(2):160-164.

[8]Xu, R., McGirt, M.J., Sutter, E.G., Sciubba, D.M., Wolinsky, J.P., Witham, T.F., Gokaslan, Z.L., Bydon, A., 2010. Biomechanical comparison between C-7 lateral mass and pedicle screws in subaxial cervical constructs. J. Neurosurg. Spine, 13(6):688-694.

Open peer comments: Debate/Discuss/Question/Opinion

<1>

Please provide your name, email address and a comment





Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - 2024 Journal of Zhejiang University-SCIENCE