Current Issue: <JZUS-A>

Journal of Zhejiang University-SCIENCE A (Applied Physics & Engineering)

ISSNs 1673-565X (Print); 1862-1775 (Online); CN 33-1236/O4; started in 2000,Monthly.


JZUS-A is a peer-reviewed physical and engineering journal, indexed by SCI-E, Ei Compendex, INSPEC, CA, SA, JST, AJ, ZM, CABI, ZR, CSA, etc. It mainly covers research in Applied Physics, Mechanical and Civil Engineering, Environmental Science and Energy, Materials Science and Chemical Engineering, etc.

Impact factor: 0.408 (2011), 0.527 (2012), 0.608 (2013), 0.882 (2014), 0.941 (2015), 1.214 (2016), 1.215 (2017), 1.369 (2018).


Journal of Zhejiang University SCIENCE A

ISSN 1673-565X(Print), 1862-1775(Online), Monthly

<<<                         CONTENTS                         >>>

Special Issue for selected papers of the 2nd International Conference on Reliability of Electrical Products and Electrical Contacts (ICREPEC 2007), Mar. 28~31, 2007, Xiamen, China

Electrical Product Reliability and Electrical Contact

Vacuum interrupter, high reliability component of distribution switches, circuit breakers and contactors

Slade Paul G., Li Wang-Pei, Mayo Stephen, Smith R. Kirkland, Taylor Erik D.

DOI: 10.1631/jzus.2007.A0335 Downloaded: 2914 Clicked: 3469 Cited: 4 Commented: 0(p.335~342) <Full Text>

Reliability of power connections

BRAUNOVIC Milenko

DOI: 10.1631/jzus.2007.A0343 Downloaded: 2305 Clicked: 3393 Cited: 9 Commented: 0(p.343~356) <Full Text>

Noise properties in breaking and loose contacts and their effect on quality degradation of digital signal

TAKAGI Tasuku

DOI: 10.1631/jzus.2007.A0357 Downloaded: 1542 Clicked: 3241 Cited: 0 Commented: 0(p.357~360) <Full Text>

Particle contamination, the disruption of electronic connectors in the signal transmission system

ZHANG Ji-gao

DOI: 10.1631/jzus.2007.A0361 Downloaded: 1759 Clicked: 3357 Cited: 0 Commented: 0(p.361~369) <Full Text>

Study on the instantaneous protection reliability of low voltage circuit breakers

LU Jian-guo, DU Tai-hang, LUO Yan-yan

DOI: 10.1631/jzus.2007.A0370 Downloaded: 1587 Clicked: 3210 Cited: 1 Commented: 0(p.370~377) <Full Text>

Transformer real-time reliability model based on operating conditions

HE Jian, CHENG Lin, SUN Yuan-zhang

DOI: 10.1631/jzus.2007.A0378 Downloaded: 2887 Clicked: 3550 Cited: 7 Commented: 0(p.378~383) <Full Text>

Failure analysis of a kind of low power connector

ZHOU Yi-lin, ZENG Ning, XU Liang-jun, JÖRGENS Stefan

DOI: 10.1631/jzus.2007.A0384 Downloaded: 1566 Clicked: 3468 Cited: 2 Commented: 0(p.384~392) <Full Text>

Approach for electrodynamic force for compensation in low voltage circuit breaker WP 630-1.2 type

LU Na, XU L.J., Miedziński B.

DOI: 10.1631/jzus.2007.A0393 Downloaded: 1788 Clicked: 3583 Cited: 0 Commented: 0(p.393~396) <Full Text>

Finite element model analysis of thermal failure in connector

WANG Xin, XU Liang-jun

DOI: 10.1631/jzus.2007.A0397 Downloaded: 1878 Clicked: 3303 Cited: 1 Commented: 0(p.397~402) <Full Text>

Modeling of contact surface morphology and dust particles by using finite element method

WANG Dong, XU Liang-jun

DOI: 10.1631/jzus.2007.A0403 Downloaded: 1615 Clicked: 3402 Cited: 7 Commented: 0(p.403~407) <Full Text>

Single neuron network PI control of high reliability linear induction motor for Maglev

FANG You-tong, FAN Cheng-zhi

DOI: 10.1631/jzus.2007.A0408 Downloaded: 1645 Clicked: 3503 Cited: 1 Commented: 0(p.408~411) <Full Text>

Dynamic performance analysis model of high-reliability EMS-Maglev system

FANG You-tong, YAO Ying-ying

DOI: 10.1631/jzus.2007.A0412 Downloaded: 1657 Clicked: 3738 Cited: 0 Commented: 0(p.412~415) <Full Text>

Simulation and reliability analysis of shunt active power filter based on instantaneous reactive power theory

CUI Yu-long, LIU Hong, WANG Jing-qin, SUN Shu-guang

DOI: 10.1631/jzus.2007.A0416 Downloaded: 2574 Clicked: 3338 Cited: 1 Commented: 0(p.416~421) <Full Text>

Random vibration analysis of switching apparatus based on Monte Carlo method

ZHAI Guo-fu, CHEN Ying-hua, REN Wan-bin

DOI: 10.1631/jzus.2007.A0422 Downloaded: 1723 Clicked: 3173 Cited: 0 Commented: 0(p.422~425) <Full Text>

Method of reliability tolerance design based on EDA technology and its application on DC hybrid contactor

WANG Shu-juan, SHA You-tao, ZHANG Hui, ZHAI Guo-fu

DOI: 10.1631/jzus.2007.A0426 Downloaded: 1516 Clicked: 3514 Cited: 3 Commented: 0(p.426~433) <Full Text>

Method of analyzing vibration characteristics of armature system of hermetically sealed electromagnetic relay

REN Wan-bin, CUI Li, LUO Fu-biao, ZHAI Guo-fu

DOI: 10.1631/jzus.2007.A0434 Downloaded: 1572 Clicked: 3400 Cited: 2 Commented: 0(p.434~438) <Full Text>

Discussion on dynamic reliability tolerance design technology of electromagnetic relay

YE Xue-rong, LIANG Hui-min, ZHAI Guo-fu

DOI: 10.1631/jzus.2007.A0439 Downloaded: 1644 Clicked: 3368 Cited: 0 Commented: 0(p.439~443) <Full Text>

Dynamics analysis of vibration process in Particle Impact Noise Detection

ZHANG Hui, ZHOU Chang-lei, WANG Shu-juan, ZHAI Guo-fu

DOI: 10.1631/jzus.2007.A0444 Downloaded: 1711 Clicked: 3951 Cited: 1 Commented: 0(p.444~448) <Full Text>

Study on the failure mechanism of Ag-Ce contacts in DC level

MENG Fan-bin, LU Jian-guo, LU Ning-yi, CHEN Zhi-chao, CHEN Qi

DOI: 10.1631/jzus.2007.A0449 Downloaded: 1555 Clicked: 3638 Cited: 0 Commented: 0(p.449~452) <Full Text>

Research on the overload protection reliability of moulded case circuit-breakers and its test device

LI Kui, LU Jian-guo, WU Yi, QIN Zhi-jun, YAO Dong-mei

DOI: 10.1631/jzus.2007.A0453 Downloaded: 1446 Clicked: 3417 Cited: 1 Commented: 0(p.453~458) <Full Text>

Testing results analysis of contact materials’ electrical contact performance

WANG Jing-qin, WANG Hai-tao, WEN Ming, ZHU Yan-cai

DOI: 10.1631/jzus.2007.A0459 Downloaded: 1719 Clicked: 3689 Cited: 2 Commented: 0(p.459~463) <Full Text>

Research of network technology for Intelligent Circuit Breaker Controller

LIU Jiao-min, FAN Tong-rang, TONG Kuan-zhang

DOI: 10.1631/jzus.2007.A0464 Downloaded: 1672 Clicked: 3688 Cited: 4 Commented: 0(p.464~468) <Full Text>

New method for capturing arc of moving on switching apparatus

LIU Jiao-min, WANG Jing-hong

DOI: 10.1631/jzus.2007.A0469 Downloaded: 1491 Clicked: 3410 Cited: 0 Commented: 0(p.469~474) <Full Text>

Reliability testing and reliability analysis of the over-load protective relay

ZHAO Jing-ying, CHEN Hong-jian, LIU Guo-jin, ZHANG Yong, WU Pin-hua

DOI: 10.1631/jzus.2007.A0475 Downloaded: 1623 Clicked: 3433 Cited: 1 Commented: 0(p.475~480) <Full Text>

Study on reliability technology of contactor relay

LIU Guo-jin, ZHAO Jing-ying, WANG Hai-tao, YANG Chen-guang, SUN Shun-li

DOI: 10.1631/jzus.2007.A0481 Downloaded: 2858 Clicked: 3284 Cited: 1 Commented: 0(p.481~484) <Full Text>

Influence of the ambient air temperature on the electrical contact reliability of electromagnetic relay

YAO Fang, ZHENG Jian-rong, HUANG Zhang-wu

DOI: 10.1631/jzus.2007.A0485 Downloaded: 1425 Clicked: 3709 Cited: 1 Commented: 0(p.485~489) <Full Text>

Design of intelligent detecting system based on wireless transmission

GUO Li-wei, LIU Dong-hui, ZHANG Xin-ling, SUN Xiao-yun

DOI: 10.1631/jzus.2007.A0490 Downloaded: 1487 Clicked: 3266 Cited: 1 Commented: 0(p.490~494) <Full Text>

Inspection-replacement policy of system under predictive maintenance

LIU Bao-you, FANG You-tong, WEI Jin-xiang, WANG Yong-liang

DOI: 10.1631/jzus.2007.A0495 Downloaded: 1373 Clicked: 3171 Cited: 1 Commented: 0(p.495~500) <Full Text>

Application of the Bayes’ theory to the failure rate evaluation of electrical apparatus

JIN Shao-hua, LU Jian-guo, WAN Yan-ping, SUN Shu-guang

DOI: 10.1631/jzus.2007.A0501 Downloaded: 1643 Clicked: 3518 Cited: 2 Commented: 0(p.501~505) <Full Text>

Technical research on optimization design of contacts of electrical connector

LV Bin, ZHOU Sheng-jun, ZHAO Lan-yan

DOI: 10.1631/jzus.2007.A0506 Downloaded: 1571 Clicked: 3452 Cited: 1 Commented: 0(p.506~510) <Full Text>

Journal of Zhejiang University-SCIENCE, 38 Zheda Road, Hangzhou 310027, China
Tel: +86-571-87952783; E-mail: cjzhang@zju.edu.cn
Copyright © 2000 - Journal of Zhejiang University-SCIENCE